THE BONY SUBSTITUTION USING ORTHOTOPIC AUTOCLAVED ALLOGRAFT IN DOGS FEMUR

Authors

  • K AMARA Tiaret University
  • M MELIZI Batna University
  • M BENAZZOUZ Constantine University 1
  • H SHNAIN Baghdad University;

Keywords:

bony substitution, orthotopic autoclaved allograft, femur, dog.

Abstract

Implantation of different lengths of orthotopic autoclaved allograft in the femur of dogs fixed with
intramedullary pin and stainless steel wire has been performed in 11 dogs, to determine the maximum
percentage of bone substitution, as well as, comparison of fenestrated and non fenestrated bony implants.
Clinical lameness and serial post operative radiographs are evaluated. Bone union in five dogs, breaking
of the implant in three cases and death of two dogs during the follow up has been observed. The
maximum percentage of the bony substitution that could be applied successfully is about 33% with the
maximum length of 6 cm. The rapid hard callus formation has been observed due to the use of perforated
implant

Author Biographies

K AMARA, Tiaret University

Institute of Veterinary Sciences

M MELIZI, Batna University

Department of Veterinary Sciences, Faculty of Sciences

M BENAZZOUZ, Constantine University 1

Department of Veterinary Sciences, Faculty of Sciences

H SHNAIN, Baghdad University;

Department of Surgery, College of Veterinary Medicine

References

- Bowerman J.W. and Hughes J.L. "Radiology of bone

graft" Clin North Am., Vol 13, (1975), pp 67-77.

- Peer L.A. "Transplantation of bone in animals"

Transplantation of tissues, Vol II, Williams & Wilkins

Company (1955), pp 152-179.

- Souter W.A. "Autogenous cancellous strip grafts in the

treatment of delayed union of long bone fractures" J

Bone Joint Surg (Br), (1969), Vol 51, pp 63-75.

- Albee F.H. "Fundamentals in bone transplantation " J

Am Med Assoc, (1923), Vol 81, pp 1429-1432.

- Brinker W.O., Flo G.L., Braden T. "Removal of bone

plates in small animals" J Am Anim Hosp Assoc,

(1975), Vol 11, pp 577-586.

- Enneking W.F., Morris J.L. "Humain autologous

cortical bone transplants" Clin Orthop, (1972), Vol 87,

pp 28-35.

- Henriksen P. "Entire segment bone transplant in a cat"

J Am Vet Med Assoc, (1979), Vol 174, pp 826-828.

- Hamon P. "Processed heterogenous bone implants as

grafts in spinal surgery" Acta Orthop Scand, (1964),

Vol 35, pp 98-116.

- Wilson J.W., Rhinelander F.W.,and Stewart C.L.

"Vascularization of chip bone graft" J Am Vet Res,

Vol 46, N° 8, pp 1691-1699.

- Kerwin S.C., Lewis D.D., Elkins A.D., Olivier

J.,Pechman R. "Deep-frozen allogeneic cancellous

bone graft in 10 dogs" Vet Surg, (1996), Vol 25, pp

-28.

- Friedlaender G.E. "Currents concepts review bonebanking"

J Bone Joint Surg, (1983), Vol 64A, pp 307-

- Schena C.J., Mitten R.W.,and Haefle W.D.

"Segmental freeze-dried and fresh cortical allograft in

canine femur: A sequential radiographic comparison

over a one-year time interval"J Am Anim Hosp Assoc,

(1984), Vol 20, pp 911-925.

- Schena C.J., Mitten R.W.,and Haefle W.D.

"Segmental freeze-dried and fresh cortical allograft in

canine femur: A sequential radiographic comparison

over a one-year time interval"J Am Anim Hosp Assoc,

(1985), Vol 21, pp 193-206.

- Henry W.B.,and Wadsworth P.L. "Retrospective

analysis of failures in the repair of severely

comminuted long bone fractures using large

diaphyseal allografts" J Am Anim Hosp Assoc,

(1981), Vol 17, pp 535-546.

- Szentimrey D., Fowler D., Johnstinson G., Wilkinson

A. "Transplantation of the canine distal ulna as a tree

vascularized bone graft" Vet Surg, (1995), Vol 24, pp

-225.

- Henry W.B.,and Wadsworth P.L. "Diaphysial

allograft in repair of long bone fractures" J Am Anim

Hosp Assoc, (1981), Vol 17, pp 525-534.

- Parrish F.F. "Allograft replacement of all or part of

the end a long bone following excision of a tumor:

Report of twenty-one cases" J Bone Joint Surg,

(1973), Vol 55A, pp 1-22.

- Boudrieau R.J. "Delayed union; non-union and

malunion" In saunders Manuel of Small Animal

Practice.Edited by S.J. Birchard & R.G. Sherding, WB

Sauders Co, pp 1096-1100.

- Braden T.D.,and Brinker W.O. "Effect of certain

internal fixation devices on functional" J Am Vet Med

Assoc, (1973), Vol 162, N° 8, pp 642-647.

- Galante J.O., Rostoker W.,and Doyle J.M. "Failed

femoral stems in total hip prostheses"" J Bone Joint

Surg, (1975), Vol 55A, pp 230-236.

Published

2010-12-01

How to Cite

AMARA, K., MELIZI, M., BENAZZOUZ, M., & SHNAIN, H. (2010). THE BONY SUBSTITUTION USING ORTHOTOPIC AUTOCLAVED ALLOGRAFT IN DOGS FEMUR. Sciences & Technology. C, Biotechnologies, (32), 37–42. Retrieved from https://revue.umc.edu.dz/c/article/view/303